The LF3051-DL is a high-performance monosilicon pressure transmitter designed by Puride, using internationally leading sensor and patented encapsulation technologies. The sensor is located on top of the metal body, away from the process medium, achieving both mechanical and thermal isolation. Glass-sintered sensor pins provide high-strength electrical insulation of the metal base, while improving circuit-design flexibility and transient-voltage (surge) protection.
| General | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model | LF3051-DL | ||||||||||||||||||
| Product Type | Single-flange level transmitter | ||||||||||||||||||
| Measured Medium | Pressure of liquids, gases or steam | ||||||||||||||||||
| Measurement Type | Differential pressure measurement, gauge pressure measurement, absolute pressure measurement | ||||||||||||||||||
| Output Signal | 4-20 mA DC with superimposed HART digital signal; RS-485 serial signal |
||||||||||||||||||
| Process Connection | Single-flange connection complying with ANSI or DIN standards | ||||||||||||||||||
| Enclosure Material | Aluminium alloy with epoxy resin coating (painted finish); stainless steel option | ||||||||||||||||||
| Fill Fluid | Silicone oil; food-grade oil | ||||||||||||||||||
| Measuring Range & Single-Sided Overload | |||||||||||||||||||
| Range Code & Span |
|
||||||||||||||||||
| The applicable measuring range depends on the transmitter range code, the flange configuration and the rated pressure. | |||||||||||||||||||
| Level Flange | |||||||||||||||||||
| Flange Type & Minimum Span |
|
||||||||||||||||||
| Span Limits & Mounting | |||||||||||||||||||
| Minimum Span | The minimum span of the single-flange level transmitter is the greater of the minimum span listed in the range table and that listed in the level flange table. The adjusted span must not be smaller than this minimum span. | ||||||||||||||||||
| Maximum Span | The maximum span is limited by the lower of the maximum span of the transmitter body and the maximum working pressure of the level flange. | ||||||||||||||||||
| Mounting Position Effect | The transmitter can be mounted directly in any position through the level flange. Optimum performance is obtained with the process flange axis in the vertical position; any position deviation produces a correctable zero offset. The electronics housing can be rotated up to 360°, and the locking screw allows it to be secured in any position. | ||||||||||||||||||
| Response & Stability | |||||||||||||||||||
| Amplifier Damping Constant | 0.1 s | ||||||||||||||||||
| Sensor & Level Flange Time Constant | 0.2–2 s, depending on the sensor range and turndown ratio | ||||||||||||||||||
| Additional Adjustable Time Constant | 0.1–60 s | ||||||||||||||||||
| Long-Term Stability | ±0.1% FS over 3 years | ||||||||||||||||||
| Environmental | |||||||||||||||||||
| Ambient Temperature | Maximum 85 °C; with display: -20 to +65 °C. The minimum depends on the fill fluid. | ||||||||||||||||||
| Storage Temperature | Maximum 85 °C. The minimum depends on the fill fluid. | ||||||||||||||||||
| Process Temperature Limit | -30 to +180 °C | ||||||||||||||||||
| Relative Humidity | 0–100% | ||||||||||||||||||
| Shock Resistance | Acceleration 50 g; duration 11 ms | ||||||||||||||||||
| Vibration Resistance | 2 g at 10–500 Hz | ||||||||||||||||||
| Electromagnetic Compatibility | In accordance with the EMC schedule (refer to the EMC compliance table) | ||||||||||||||||||
| Pressure Limits | |||||||||||||||||||
| Transmitter Body Pressure Limit | From 3.5 kPa absolute up to the rated pressure. Proof pressure up to 1.5 times the rated pressure, applied simultaneously to both sides of the transmitter. | ||||||||||||||||||
| Level Flange Rated Pressure | ANSI: Class 150 to Class 600 DIN: PN 16 to PN 100 |
||||||||||||||||||
| Single-Sided Overload Limit | The low-pressure side is limited by the rated pressure of the transmitter body, and the high-pressure side by the rated pressure of the level flange. A correctable zero shift may occur. | ||||||||||||||||||
| Materials & Mechanical Construction | |||||||||||||||||||
| Diaphragm Materials | Stainless steel 316L; Hastelloy C-276; tantalum; gold-plated option | ||||||||||||||||||
| Process Connection Materials | Stainless steel 304 or 316 (optional) | ||||||||||||||||||
| Nuts and Bolts | Stainless steel (A2-70); zinc-plated carbon steel (property class 12.8) | ||||||||||||||||||
| Transmitter Housing | Aluminium alloy with epoxy resin coating (painted finish); stainless steel option | ||||||||||||||||||
| Fill Fluid | Silicone oil; food-grade oil | ||||||||||||||||||
| Flange Configuration | Flat diaphragm or extended diaphragm | ||||||||||||||||||
| Nominal Flange Size | DN 50 / 2 in; DN 80 / 3 in; DN 100 / 4 in | ||||||||||||||||||
| Flange Standard | ANSI or DIN | ||||||||||||||||||
| Electrical Connection & Mechanical Data | |||||||||||||||||||
| Electrical Connection | M20 × 1.5 cable gland | ||||||||||||||||||
| Terminal Wire Size | 0.5–2.5 mm² conductors | ||||||||||||||||||
| Power Supply & Load Conditions | 24 VDC | ||||||||||||||||||
| Communication Interfaces | HART; RS-485 (depending on configuration) | ||||||||||||||||||
| Ingress Protection Rating | IP65; IP67 for explosion-proof models | ||||||||||||||||||
| Weight | DN 50 / 2 in: approx. 7–10 kg DN 80 / 3 in: approx. 8–11 kg DN 100 / 4 in: approx. 9–12 kg |
||||||||||||||||||
The Puride LF3051-DL single-flange level transmitter can be installed in different orientations using the level flange. For optimum performance, the process flange axis should be positioned vertically. Any deviation from the recommended installation orientation may introduce a zero shift, which can be corrected through zero-point adjustment.
The electronics housing can be rotated up to 360° and secured in the desired position using the locking screw, facilitating convenient wiring, display viewing and on-site commissioning.
![]()
![]()
![]()
| Level Flange Dimension Table | ||||||||||
| Nominal Size | Rated Pressure |
A |
B |
C |
D |
E |
F |
f |
Flange Bolts | |
| No. of Bolts |
Thread |
|||||||||
|
DN25 |
PN10/40bar |
115 |
85 |
65 |
18 |
4 |
14 |
2 |
4 |
M12 |
|
PN63/100bar |
140 |
100 |
65 |
24 |
4 |
18 |
2 |
4 |
M16 |
|
|
DN50 |
PN10/40bar |
165 |
125 |
95 |
20 |
4 |
18 |
2 |
4 |
M16 |
|
PN63bar |
180 |
135 |
95 |
26 |
4 |
22 |
2 |
4 |
M20 |
|
|
PN100bar |
195 |
145 |
95 |
28 |
4 |
26 |
2 |
4 |
M24 |
|
|
DN80 |
PN10/16bar |
200 |
160 |
127 |
20 |
8 |
18 |
2 |
8 |
M16 |
|
PN25/40bar |
200 |
160 |
127 |
24 |
8 |
18 |
2 |
8 |
M16 |
|
|
PN63bar |
215 |
170 |
127 |
28 |
8 |
22 |
2 |
8 |
M20 |
|
|
PN100bar |
230 |
180 |
127 |
32 |
8 |
26 |
2 |
8 |
M24 |
|
|
DN100 |
PN10/16bar |
220 |
180 |
157 |
20 |
8 |
18 |
2 |
8 |
M16 |
|
PN25/40bar |
235 |
190 |
157 |
24 |
8 |
22 |
2 |
8 |
M20 |
|
|
PN63bar |
250 |
200 |
157 |
30 |
8 |
26 |
2 |
8 |
M24 |
|
|
PN100bar |
265 |
210 |
157 |
36 |
8 |
30 |
2 |
8 |
M27 |
|
|
2’’ |
150psi |
150 |
120.7 |
95 |
19.5 |
4 |
19 |
2 |
4 |
M16 |
|
300psi |
165 |
127 |
95 |
22.7 |
8 |
19 |
2 |
8 |
M16 |
|
|
600psi |
165 |
127 |
95 |
32.4 |
8 |
19 |
2 |
8 |
M16 |
|
|
3’’ |
150psi |
190 |
152.4 |
127 |
24.3 |
4 |
19 |
2 |
4 |
M16 |
|
300psi |
210 |
168.3 |
127 |
29 |
8 |
22 |
2 |
8 |
M20 |
|
|
600psi |
210 |
168.3 |
127 |
38.8 |
8 |
22 |
2 |
8 |
M20 |
|
|
4’’ |
150psi |
230 |
190.5 |
157 |
24.3 |
8 |
19 |
2 |
8 |
M16 |
|
300psi |
255 |
200 |
157 |
32.2 |
8 |
22 |
2 |
8 |
M20 |
|
| Brand Name: | Puride |
| Model Number: | LF3051-DL |
| MOQ: | 1piece |
| Price: | Price on request |
| Payment Terms: | L/C,T/T |
| Supply Ability: | 5,000 sets / month |